Click here to make tpub.com your Home Page

Page Title: Hydraulic Fluid Manifold.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-4920-405-13&P
(a) Route the pressure compensator con-
(b) Connect the fluid outlet line and the
trol assembly through the opening in,
level indicator line.
the control panel.
(b) Remove the tape that you put over the
(9) Selector Valves. To install SUCTION
end of the pressure compensator as-
PRESSURE FILTER-OUT valve (21, fig-
sembly when you removed it. Be
ure 2-1), RESERVOIR VALVE (15), or
careful that you do not let the plunger
HIGH PRESS BYPASS VALVE (19), pro-
and ball bearings fall out of the pres-
ceed as follows:
s u r e compensator assembly. Slide
this end of the pressure compensator
(a) With the handle removed from the
valve, insert the valve into the control
assembly into the pressure compensa-
tor coupling on the hydraulic pump,
panel from the rear. Attach the valve
and tighten the nut to fasten the pres-
to the control panel with the mounting
sure compensator assembly to the
hardware.
hydraulic pump.
(b) Check the tags you attached to the hy-
draulic tubing when you removed the
(5) Hydraulic Fluid Manifold. To install hy-
valve. Connect the tubing to the cor-
draulic fluid manifold (6, figure 4-6),
rect ports of the valve.
proceed as follows:
(c) Install the handle on the front end of
the valve using one screw.
(a) Install the temperature switch on the
hydraulic fluid manifold. Place the
(10) Flow Control Valve. To install FLOW
hydraulic fluid manifold in position on
CONTROL VALVE (12, figure 2-1), pro-
the test stand chassis.
ceed as follows:
(b) Connect the electrical wiring to the
temperature switch.
(a) With the handle of the valve removed,
ins tall the valve in the proper open-
(c) Connect the hydraulic tube couplings
ing of the control panel. Install the
to the ports of the hydraulic fluid
attaching hardware.
manifold.
(b) Check the tags you attached to the hy-
( 6 ) High Pressure Filter Assembly. To in-
draulic tubing when you removed the
stall high pressure filter assembly (4,
valve. Connect the hydraulic tubing to
figure 4-6), proceed as follows:
the valve.
(c) Install the knob on the valve shaft,
(a) Connect the inlet and outlet hydraulic
and tighten the setscrew in the knob.
lines to the high pressure filter as-
sembly. Hold the filter assembly to
(11) Shutoff Valves.  To install FLUID PRESS
relieve the weight while you are
GAGE SHUTOFF valve (22, figure 2-1) or
making these connections.
COMPENSATOR SHUTOFF VALVE (17),
(b) Connect the switch and the switch by-
proceed as follows:
pass lines.
(a) With the handle removed from the
(7) Low Pressure Filter Assembly. To in-
valve, install the valve on the control
stall low pressure filter assembly (7, fig-
panel.
ure 4-6), proceed as follows:
(b) Check the tags you attached to the
tubing when you removed the valve.
(a) Position the low pressure filter as-
Connect the tubing to the valve.
sembly against the test stand chassis.
(c) Install the handle on the valve with
Install four bolts through the mounting
one screw.
bands into the test stand chassis.
( 1 2 ) Pressure Gages.  To install FLUID PRES-
(b) Connect the inlet and outlet couplings.
SURE GAGE (5, figure 2-1) or SUCTION
( 8 ) Hydraulic Fluid Reservoir. To install
PRESSURE GAGE (7), proceed as follows:
hydraulic fluid reservoir (1, figure 4-6),
proceed as follows:
(a) Position the gage in the proper open-
ing on the control panel and install the
NOTE
gage mounting hardware.
(b) Connect the hydraulic tubing to the
The hydraulic pump must be installed be-
port at the rear of the gage.
fore you install the hydraulic fluid
(13) Temperature Gage. To install FLUID
reservoir.
TEMP GAGE (9, figure 2-1), proceed as
follows:
(a) Position the hydraulic fluid reservoir
on the test stand frame. Attach it to
(a) Position the gage in the proper open-
the frame with the mounting bolts,
ing on the control panel and install the
l o c k w a s h e r s , and nuts.
gage mounting hardware.
4-41

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business