APPENDIX E
CONVERTING THE MSU-1 MOBILE SUPPORT UNIT FROM
MIL-H-5606 TO MIL-H-83282 HYDRAULIC FLUID
E-13. Start unit as shown in TM paras 3-9 and 310.
E-1. To drain pressurized fluid from accumulator open
NOTE Do not use buddy start system during flushing
the hand pump bypass valve as shown in TM 55-1730-
procedures.
216-14, para 3-4(d), page 38 and allow the accumulator
fluid to return to the reservoir. Close the bypass valve
after fluid has passed to the reservoir.
E-14.
Perform steps specified in TM para 3-18,
Preparation for Hydraulic Service. Set volume control
E-2. To drain reservoir. open drain valve at bottom.
for 10 gallons per minute and compensator for 1500 psi.
E-3. Drain hydraulic system components as shown in
E-15. Close high pressure bypass valve, open flushing
TM para 2-1(9)(b), page 33.
manifold valve, and operate the stand for five minutes
in the flushing mode.
E-4. Drain high pressure filter, pump case filter, and
start system filter.
E-16. Close flushing manifold valve. Operate stand in
this mode for 30 seconds. Open high pressure bypass
E-5.  Reassemble filters, replace all plugs and caps
valve. Operate stand in this mode for one minute.
removed per para E-3, and close reservoir drain valve.
E-17. Prepare stand for propulsion mode as shown in
E-6.  Fill reservoir with 10 gallons of MIL-H-83282
TM para 3-30, page 43, do not engage drive pins.
hydraulic fluid.
Operate stand with control lever on tongue in full
forward position for two minutes, then in full reverse
position for two minutes.
E-7. Refill high pressure pump case per TM para 2-
1(9)c, NOTE, page 33.
E-18. Return propulsion selector valve to HYDRAULIC
OUTPUT position.
E-8. Place reservoir selector valve in "SERVICE UNIT
RESERVOIR" mode.
E-19. Shut down stand.
E-9. Connect pressure hoses and fill hose and flushing
E-20. Repeat steps E-1 thru E-19 twice.
manifold to test stand ref TM para 3-18, page 41. Open
fill hose shut off valve.
E-21.  Drain stand see steps E-1 thru E-5.  Refill
reservoir with 15 gallons of MIL-H-83282 hydraulic fluid.
E-10. Use hand pump, to pump the accumulator up to
at least 2000 psi.
E-22. Refill high pressure pump case per step E7.
E-11. Set pump volume control for maximum, depress
E-23. Circulate fluid through stand as shown in steps E-
start handle and hold until oil appears in the sight tube
10 and E-11.
ref TM para 3-7, page 39.
E-12. Pump the accumulator up to at least 2000 psi.
E-1/(E-2 blank)