TM 1-1730-231-13&P
2.
Interval column: has checks (x) placed in the appropriate interval column in front of the procedure to be performed.
3.
Item to be inspected/procedures column: lists the item to be inspected and procedure to do that.
4.
Equipment is not ready/available column: lists the status for the check only if the cart is not ready for operation.
TABLE 3-1. Inspection Requirements
INTERVAL DEFINITIONS
D - DAILY Q - QUARTERLY S - SEMI-ANNUALLY A - ANNUALLY
INTERVAL
ITEM
ITEM TO BE INSPECTED/PROCEDURE:
EQUIPMENT IS NOT
NO.
CHECK FOR AND HAVE REPAIRED,
READY/AVAILABLE IF:
D
Q
S
A
FILLED, OR ADJUSTED AS NEEDED
CABINET/FRAME
1
x
Access door and control panel
cover hinges for free movement;
lubricate if needed.
2
x
Chipped paint and metal
exposure; service in accord-
ance with TM 43-0139.
3
x
Identification plates and
markings for legibility.
MANIFOLD ASSEMBLY
4
x
Loose mounting.
5
x
Pressure gage for cracked or
Gage is not read-
broken glass.
ing correctly.
6
x
Pressure gage calibration -
Calibration date
check calibration date
is expired.
7
x
Manual flow regulators leak-
age at stem due to damaged
O-ring.
8
x
Damage to coils of solenoid
Solenoid valves
valves.
not operating
correctly.
3-3
|