TM 1-4920-446-13 & P 3-74.  Filter assemblies - Replace 3-74 This task covers:  Removal, Installation, Disassembly, and Reassembly INITIAL SETUP Tools: Tool Kit, Aircraft Mechanics General, NSN  5180-00-323-4692 Material Required: Antiseize tape MIL-T-27730 Parts Required: Filter assembly HP 50223 Filter assembly LP 58342-01 Personnel Required: MOS 67 - series Equipment Condition: Para.  3-18 cabinet assembly removed. Test stand shut down and pressure exhausted. NOTE Tag all disconnected tubing and lines to ease reinstallation. HIGH PRESSURE FILTER Removal: 1. Disconnect  high pressure differential switch from both sides of high pressure filter.  Be careful not to damage differ- ential switch, as these two connections are the only support for the switch. 2. Set differential switch aside being careful not to damage the electrical wire. 3. Disconnect hydraulic lines from filter.   Retain "T" joints with filter assembly. 4. Remove two screws holding filter assembly to mounting bracket. 5. Remove filter assembly from unit. GO TO NEXT PAGE 3-95

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business