SECTION III (Con't.)
Ammeter Shows Excessive Charge.
3-17
Probable cause
Possible remedy
Battery run down ------------------------ Charge battery
Generator regulator defective ----------- Replace a defective
regulator
Generator field winding grounded -------- Replace generator.
3-18
Ammeter Needle Fluctuates Rapidly.
Probable cause
Possible remedy
Electrical connections shorted
or loose - - - - - - - - - - - - - - - - - - - - - - - Repair short circuits
and tighten loose
connections
Generator commutator has high mica ------ Report to depot
maintenance.
Wheel Wobbles.
3-19
Possible remedy
Probable cause
Wheel bent - - - - - - - - - - - - - - - - - - - - - - - Replace the wheel.
Wheel loose on the hub------------------ Tighten wheel mounting
bolts.
Wheel bearings incorrectly adjusted ----- Adjust wheel bearing.
Wheel Bearings Overheat.
3-20
Probable cause
Possible remedy
Wheel bearings lack lubrication --------- Lubricate wheel bear-
ings.
Wheel bearings incorrectly adjusted ----- Adjust wheel bearings.
3-21
Tire Wear Abnormal or uneven.
Possible remedy
Probable cause
Wheel loose on the hub------------------ Tighten wheel mounting
bolts.
Steering tie rod incorrectly
adjusted - - - - - - - - - - - - - - - - - - - - - - - Adjust tie rods.
3-22
Brake Does Not Hold.
Probable cause
Possible remedy
Normal wear - - - - - - - - - - - - - - - - - - - - - - Adjust brakes.
Defective brake assembly ---------------- Repair or replace
brake assembly.
-55-
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |