TM 1-1730-231-13&P 3-31.  HYDRAULIC PIPING 3-31 This task covers: A.  INSPECTION B.  REPAIR (AVIM) C.  REMOVAL D.  INSTALLATION E.  TEST (AVIM) INITIAL SETUP Tools Tool Kit, Hydraulic, NSN 5180-00-323-4891 Shop Set, AVIM, Hydraulic, NSN 4920-00-165-1454 Personnel Required MOS 67 and MOS 68H General Safety Instructions WARNING Be sure that all electrical power is removed from the    unit    before    beginning    any    maintenance operation. To  avoid  personnel  injury,  the  pump  must  be shut  down  before  beginning  any  maintenance operation. NOTE Tag  all  disconnected  tubing  and  lines  to  ease reinstallation. A. INSPECTION Check all hydraulic lines, tubing, fittings, and manifold for damage, loose connections, and leakage. B. REPAIR (AVIM) 1. Repair or replace all damaged or worn lines, tubing, fittings, and manifold. 2. Tighten all loose connections. C. REMOVAL Disconnect and remove hydraulic lines, tubing, fittings, and manifold only to the extent necessary for the repair or replacement of damaged or worn parts. GO TO NEXT PAGE 3-45

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business