TM 1-1730-231-13&P
3-30. RESERVOIR TANK - Continued
3-30
8.
Install cover (8) on reservoir tank (2) with screws (6) and lock washers (7).
9.
Install drain plug (5) at the bottom of reservoir tank. Ensure it is tightened fully.
10. Fill reservoir tank to the center of the OPNL LEVEL sight glass (1) with MIL-H-5606 or MIL-H-83282 hydraulic fluid.
C.
REMOVAL
1.
Unscrew drain plug (5) at the bottom of reservoir tank (2) and drain it. Reservoir tank contains approximately 5
gallons of hydraulic fluid at REMOVE FLUID sight glass (1) level.
2.
Disconnect return line from upper fitting (3) and suction line from lower fitting (4).
3.
Remove four mounting nuts (12) and screws (13).
CAUTION
When moving reservoir tank (2), care should be
taken to avoid damaging fittings (3 and 4).
4.
Remove reservoir tank off the hydraulic cart.
D.
INSTALLATION
CAUTION
When moving reservoir tank (2), care should be
taken to avoid damaging fittings (3 and 4).
1.
Position reservoir tank (2) on hydraulic cart.
2.
Install four mounting screws (13) and nuts (12).
3.
Connect return line at upper fitting (3) and suction line at lower fitting (4).
4.
Install drain plug (5) at the bottom of reservoir. Ensure it is tightened fully.
5.
Fill reservoir tank to the center of the OPNL LEVEL sight glass (1) with MIL-H-5606 or MIL-H-83282 hydraulic fluid.
END OF TASK
3-44
|