TM 1-1730-231-13&P
3-30. RESERVOIR TANK - Continued
3-30
3.
REPAIR (AVIM)
CAUTION
When moving reservoir tank (2), care should be
taken to avoid damaging fittings (3 and 4).
1.
Unscrew drain plug (5) at the bottom of reservoir tank (2) and drain it. Reservoir tank contains approximately 5
gallons of hydraulic fluid at REMOVE FLUID sight glass (1) level.
2.
Remove six screws (6) and lock washers (7) and lift off cover (8) from reservoir tank.
3.
Discard gasket (9).
4.
Clean and inspect interior.
5.
Check suction strainer (10), filler/breather (11), and sight glasses (1).
6.
Repair any damage or replace broken parts as necessary.
7.
Install new gasket (9).
GO TO NEXT PAGE
3-43
10
|