TM 1-1730-231-13&P
3-34. START RELAY, ELECTROMAGNETIC INTERFERENCE FILTER, AND CIRCUIT BREAKER
3-34
This task covers:
A. INSPECTION
B. REMOVAL
C. INSTALLATION
INITIAL SETUP
Tools
Tool Kit, Electrical, NSN 5180-00-323-4915
Personnel Required
MOS 67 and MOS 68X
Equipment Condition
Equipment Condition Paras.
Motor and Pump Removed
3-17 and 3-32
General Safety Instructions
WARNING
Be sure that all electrical power is removed from the unit before
beginning any maintenance operation.
A.
INSPECTION
Check performance of start relay (1), electromagnetic interference filter (2), and circuit breaker (3) during normal
operation or troubleshooting.
B.
REMOVAL
1.
Remove six screws (4) and lock washers (5) and lift off rear case plate (6).
2.
Remove motor (7) from case (8) in accordance with paragraph 3-32 removal instructions.
NOTE
Tag all disconnected wiring to ease reinstallation.
3.
Remove attaching hardware and remove wires from start relay (1), electromagnetic interference filter (2), and circuit
breaker (3).
GO TO NEXT PAGE
3-52
|