3-34. START RELAY, ELECTROMAGNETIC INTERFERENCE FILTER,
AND CIRCUIT BREAKER - Continued
3-34
4.
Remove two screws (9), flat washers (10), nuts (11), and remove start relay (1) from electromagnetic
interference filter (2).
5.
Remove two screws (12) and nuts (13) and remove circuit breaker (3) from electromagnetic
interference filter (2).
6.
Remove attaching hardware between bracket (14) and motor terminal and remove electromagnetic
interference filter (2).
C.
INSTALLATION
1.
Attach circuit breaker (3) to electromagnetic interference filter (2) with two screws (12) and nuts (13).
2.
Attach start relay (1) to electromagnetic interference filter (2) with two screws (9), flat washers (10), and
nuts (11).
3.
Attach electromagnetic interference filter bracket (14) to motor terminal with it's attached hardware.
4.
Connect wiring to start relay (1), electromagnetic interference filter (2) circuit breaker (3) using
electrical schematic (Figure 1-4) and tags as a guide.
5.
Attach motor (7) to case (8) in accordance with paragraph 3-32 installation instructions.
6.
Place rear case plate (6) on case (8) and secure with six screws (4) and lock washers (5).
END OF TASK
3-53
|