TM 5-2350-378-23&P
0006
ALL HYDRAULIC FUNCTIONS INOPERATIVE - Continued
1
2
3
4
T00418HDC
Figure 15. Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Can hydraulic pressure be adjusted to 3,950-4,050 psi (27,235-27,95 kPa)?
DECISION
YES - Verify problem is solved.
NO - Replace DCV bank (TM 5-2350-262-20).
STEP
9.
Check if vehicle rises within two minutes.
a.
Start engine.
b.
Check if vehicle rises.
CONDITION/INDICATION
Does vehicle "rise" (within two minutes) when engine is started with SPRUNG/UNSPRUNG lever in SPRUNG?
DECISION
YES - Go to Step (10).
NO - Go to Step (11).
03/15/2011Rel(1.8)root(tswp)wpno(T00004)