APRON WILL NOT RAISE - Continued
Figure 10. Apron Cylinders Leakage Test.

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  60    61    62    63    64  65  66    67    68    69    70  
img
.
TM 5-2350-378-23&P
0008
APRON WILL NOT RAISE - Continued
2
1
T00613HDC
Figure 9. Apron Cylinders Oil Flow Test.
CONDITION/INDICATION
Is there oil flow from both apron cylinder circuit 19 hoses?
DECISION
YES - Go to Step (8).
NO - Clear blockage or replace obstructed line(s).