Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  95    96    97    98    99  100  101    102    103    104    105  
img
.
TM 5-2350-378-23&P
0011
EJECTOR DOES NOT EXTEND OR RETRACT - Continued
STEP
8.
Perform ejector circuit pressure check using HDC.
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless
ejector lock is engaged. Failure to comply may result in severe injury or death to
personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in
bowl to observe roller guide travels. Failure to comply may result in severe injury or
death to personnel.
When folding dozer blade, work on blade latches from side of vehicle only. Do not
stand in front of dozer blade while retracting ejector. Failure to comply may result in
severe injury or death to personnel.
a.
Reset all HDC solenoid valves by selecting RESET VALVES button (Figure 13, Item 1) on HDC
control box.
1
T00919HDC
Figure 13. Hydraulic Diagnostic Center (HDC) Control Box.
0011-13