HYDRAULIC OIL OVERHEATS - Continued
Figure 9. Suspension Relief Valve.

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  159    160    161    162    163  164  165    166    167    168    169  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
STEP
12.
Perform suspension relief valve adjustment using HDC.
WARNING
Before performing any hydraulic troubleshooting in the bowl, move the ejector
forward and engage the ejector lock. Failure to comply may result in severe injury
to personnel.
Do not operate ejector when personnel are in bowl. Do not work in bowl unless
ejector lock is engaged. Failure to comply may result in severe injury or death to
personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in
bowl to observe roller guide travels. Failure to comply may result in severe injury or
death to personnel.
When folding dozer blade, work on blade latches from side of vehicle only. Do not
stand in front of dozer blade while retracting ejector. Failure to comply may result in
severe injury to personnel.
a.
Reset all HDC solenoid valves by selecting RESET VALVES button (Figure 7, Item 5) on HDC control
box.
2
1
3
4
5
T01311HDC
Figure 7. Hydraulic Diagnostic Center (HDC) Control Box.
b.
Manually close ejector inhibit ball valve V23 (Figure 8, Item 1) on DCV bank.
0015-10
03/15/2011Rel(1.8)root(tswp)wpno(T00013)