s. Remove the six screws (43) that secure the
u. Mark the position of the ball bearings (49)
seal retainer (42) to the port block (52) and
on the shaft and sleeve assembly and press the
remove the seal retainer. Remove the O-ring
shaft out of the bearings and spacers (50).
packing (45) from the seal retainer. Remove
Caution: Note the bearing surfaces contact-
the seal (44) from the seal retainer only if
ing the spacers. These are preloaded bearings
defective.
and must be reassembled exactly as removed.
t. Remove the shaft and sleeve assembly (51)
v. Remove the 8 screws (38 and 40) that se-
with attached bearings from the port block.
Bend the tabs of the washer (48) away from
cure the suction flange (37) and the pressure
the lock nut (47) and remove the nut and
flange (39) to the port block (52) and remove
washer.
the flanges and 2 O-ring gaskets (41).