SECTION I (Con't.)
(E) Slowly close the fluid bypass valve.
WARNING:
DO NOT CONNECT OR DISCONNECT ANY HOSES WITH THE
FLUID BYPASS VALVE CLOSED AND THE TEST STAND IN
OPERATION.
DO NOT REPOSITION THE OUTLET SELECTOR VALVE WITH
CAUTION:
THE FLUID BYPASS VALVE CLOSED AND THE TEST STAND
INOPERATION.
(F) Adjust the high pressure relief valve to relieve pressure at
approximately 200 psi above the system pressure of the unit
under test. Clockwise rotation of the relief valve knob
increases pressure setting, counterclockwise rotation
decreases pressure setting.
CAUTION: 2150 RPM MUST BE MAINTAINED ON ENGINE.
(G) Adjust the compensator control until the fluid pressure gage
indicates pressure slightly higher than the maximum pressure
of the system being tested.
CAUTION: ADJUST THE COMPENSATOR CONTROL FOR A ZERO READING
ON THE FLUID PRESSURE GAGE WHEN THE COMPENSATOR
IS NOT IN USE.
(H) Open the flow control valves and proceed with the test
operation as directed by the manufacturer's specifications
for the system under test.
(I) Close reservoir shut-off valve.
1-46
Movement to a New Site.
(A) Shut down and disconnect the test stand from the system
Coil the hose assemblies and stow them in
being tested.
the rear compartment of the test stand.
-32-