SECTION III (Con't.)
HYDRAULIC SYSTEM
Inspect- 50 100
ion
hour hour
Tighten all tube connections. Replace any
X
X
damaged or defective tube or fitting.
High Pressure filter assembly. Inspect the filter
X
X
X
for dirty or clogged condition resulting in excess-
ive pressure drop.
Remove and replace the filter element.
X
X
Thermoswitch. Inspect the thermoswitch for corr-
X
X
X
ect temperature response and for secure install-
ation.
Replace a defective or damaged thermoswitch.
X
X
Troubleshooting.
3-7
General.
This section provides information useful in diagnosis
and correction, inspection, operation, or failure of the hydraulic
test stand, or any of its components.
Each trouble symptom stated
is followed by a list of probable causes of the trouble. The possible
remedy recommended is described opposite the probable cause.
3-8
Engine Hard to Start or Fails to Start.
Possible remedy
Probable cause
Battery defective ---------------------------
Charge or replace de-
fective battery
Choking insufficient-----------------------
Inspect the choke
valve for full open
or closed position.
Battery cables loose on terminals ----------
Tighten loose connect-
ions.
Ignition switch faulty --------------------
Replace switch
Battery cable loose on armature relay ------
Tighten loose conn-
ections.
Carburetor flooded----------------------------
Remove spark plugs
and crank the engine
several times to
drive out rich fuel
mixture.
No ignition spark -------------------------
Test the spark
|