TM 1-1730-231-13&P
3-27. FILLER/BREATHER AND SPECIAL ADAPTER
3-27
This task covers:
A. INSPECTION
B. REMOVAL
C. INSTALLATION
INITIAL SETUP
Tools
Tool Kit, Hydraulic, NSN 5180-00-323-4891
Personnel Required
MOS 67 and MOS 68H
General Safety Instructions
WARNING
Be sure that all electrical power is removed from
the unit before beginning any maintenance
operation.
To avoid personnel injury, the pump must be
shut down before beginning any maintenance
operation.
A.
INSPECTION
Unscrew filler/breather cap (1) and inspect special adapter (2) and strainer for physical damage.
B.
REMOVAL
1.
Unscrew drain plug (3) at the bottom of reservoir tank (4) and drain it. Reservoir tank contains approximately 5
gallons of hydraulic fluid if level is till REMOVE FLUID sight glass.
2.
Remove six screws (5) and lock washers (6) and lift off reservoir cover (7). Be careful gasket (8) may come out with
the reservoir cover (7).
3.
Remove six nuts (9), lock washers (10), and screws (11).
4.
Lift off filler/breather (1) and special adapter (2) along with lanyard (12) from reservoir cover (7).
GO TO NEXT PAGE
3-35
|