TM 1-1730-231-13&P
3-27. FILLER/BREATHER AND SPECIAL ADAPTER - Continued
3-27
C.
INSTALLATION
1.
Position filler/breather (1) and special adapter (2) along with lanyard (12) on reservoir cover (7).
2.
Secure filler/breather (1) with six screws (11), lock washers (10), and nuts (9).
3.
If gasket (8) was removed, place it such that the holes match at the reservoir opening.
4.
Place reservoir cover (7) on reservoir opening and secure with six lock washers (6) and screws (5).
5.
Install drain plug (3) at the bottom of reservoir tank (4). Ensure it is tightened fully.
6.
Fill reservoir tank to the center of the OPNL LEVEL sight glass (13) with MIL-H-5606 or MIL-H-83282 hydraulic fluid.
END OF TASK
3-36
|