HYDRAULIC OIL OVERHEATS - Continued
HYDRAULIC OIL OVERHEATS - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  167    168    169    170    171  172  173    174    175    176    177  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
e.
Loosen jam nut (Figure 15, Item 6) on main relief valve 13R (Figure 15, Item 1).
f.
For 13R (Figure 15, Item 1); have assistant simultaneously hold EJECTOR CONTROL lever in BACK
while holding right-hand SUSPENSION CONTROL lever in RAISE.
g.
Rotate adjusting screw (Figure 15, Item 5) on main relief valve 13R (Figure 15, Item 1) clockwise to
increase pressure or counterclockwise to decrease pressure.
1
2
6
3
5
4
T01323HDC
Figure 15. Main Pump Relief Valves.
h.
Once indication from transducer T-3 on HDC display (Figure 16, Item 1) hydraulic pressure is within
desired limits, tighten jam nut (Figure 15, Item 6).
1
2
3
4
T01324HDC
Figure 16. HDC Control Valve.
i.
For 13L (Figure 15, Item 4); repeat previous steps for main relief valve 13L (Figure 15, Item 4) using left-
hand SUSPENSION CONTROL lever.