HYDRAULIC OIL OVERHEATS - Continued
HYDRAULIC OIL OVERHEATS - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  171    172    173    174    175  176  177    178    179    180    181  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
STEP
17.
Perform suspension raise/lower relief valve adjustment using HDC.
a.
Reset all HDC solenoid valves by selecting RESET VALVES button (Figure 19, Item 5) on HDC control
box.
1
2
3
4
5
T01330HDC
Figure 19. Hydraulic Diagnostic Center (HDC) Control Box.
b.
For port 3R relief valve (Figure 20, Item 2); loosen jam nut (Figure 20, Item 3) on port 3R suspension
raise/lower relief valve (Figure 20, Item 2).
2
1
3
3
4
4
T01331HDC
Figure 20.
Suspension Relief Valve Port 3L and Port 3R.
c.
Using LINE UP or LINE DOWN button (Figure 19, Item 3) select V15 on HDC display
(Figure 19, Item 2).
0015-22