TM 5-2350-378-23&P
0016
LEFT REAR CORNER DOES NOT RAISE IN SPRUNG OR UNSPRUNG MODE - Continued
CONDITION/INDICATION
Is #3 left actuator leaking internally?
DECISION
YES - If transducer T-7 pressure is less than 2,500 psi (17,238 kPa), replace No. 3 left actuator
(TM 5-2350-262-20).
NO - If transducer T-7 pressure is equal or greater than 2,500 psi (17,238 kPa), then go to Step (5).
STEP
5.
Check for binding in No. 3 left actuator.
NOTE
Have suitable container ready to catch oil.
a.
Disconnect INTMD SPNSN UNIT-2 hose (Figure 4, Item 10) from adapter (Figure 4, Item 9) at port 2
(Figure 4, Item 8), and disconnect LH 3 SPNSN UNIT-7 TEE tube (Figure 4, Item 1) and NO 3 SPNSN
UNIT-7 TEE hose (Figure 4, Item 2) from elbow (Figure 4, Item 3) and tee (Figure 4, Item 4) at port 7
(Figure 4, Item 7) on No. 3 left actuator (Figure 4, Item 5).
b.
Plug all lines.
c.
Check for binding in No. 3 left actuator (Figure 4, Item 5) by using a prybar (Figure 4, Item 6) to determine
if No. 3 lift road-wheel can be moved up or down.
2
3
1
4
5
7
6
10
8
9
T01407HDC
Figure 4.
No. 3 Left Actuator.
d.
Reconnect lines.