TM 5-2350-378-23&P
0021
APPARENT HYDRAULIC DIAGNOSTIC CENTER (HDC) SYSTEM PROBLEM - Continued
STEP
19.
Check for 28 VDC at Y connector input terminal of HDC circuit breaker.
a.
Remove end of lead assembly 12496957 (Figure 20, Item 2) from other terminal of "Y" connector.
b.
Check for 28 VDC on "Y" connector terminal going to input terminal of HDC circuit breaker.
1
2
T01920HDC
Figure 20. Hydraulic Diagnostic Center (HDC) Simplified Power Input Circuit Components.
CONDITION/INDICATION
Is 28 VDC present at "Y"-connector terminal going to input terminal of HDC circuit breaker?
DECISION
YES - Replace lead assembly 12496957 (WP 0029).
NO - Replace "Y" connector 7982404 (Figure 20, Item 1) (WP 0029).