TM 5-2350-378-23&P
0035
DISASSEMBLY
CAUTION
Disassembly should be performed in a clean environment and protective dust covers or
caps should be installed on all openings to prevent contamination. Dirt can damage parts
and cause malfunctions.
When securing primary manifold in vise, exercise extreme care not to mar any surfaces
or damage components.
1.
Remove 11 adapters (Figure 1, Item 7), 11 O-rings (Figure 1, Item 2), three adapters (Figure 1, Item 1), and
three O-rings (Figure 1, Item 2), from primary manifold (Figure 1, Item 3). Discard O-rings.
2.
Remove adapter (Figure 1, Item 12), O-ring (Figure 1, Item 13), adapter (Figure 1, Item 8), O-ring
(Figure 1, Item 2), adapter (Figure 1, Item 11), and O-ring (Figure 1, Item 2) from primary manifold
(Figure 1, Item 3). Discard O-rings.
3.
Remove five plugs (Figure 1, Item 5), five O-rings (Figure 1, Item 4), plug (Figure 1, Item 9), O-ring
(Figure 1, Item 10), six plugs (Figure 1, Item 6), and six O-rings (Figure 1, Item 2) from primary manifold
(Figure 1, Item 3). Discard O-rings.
0035-2