Page Title: Table 2-2. Function of Startup Panel Controls
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 55-4920-405-13&P
Table 2-1. Function of Main Panel Controls and Instrumentation - Continued
Function
Description
Index No.
Provides means for directing pump output back to suction
19
HIGH PRESS BYPASS VALVE
return; used with HIGH PRESS RELIEF VALVE and
control
PRESSURE COMPENSATOR to set up fluid flow; dumps
pressure
20
Lights when low pressure filter differential fluid pres-
L P P indicator
sure reaches 10 PSI, thereby indicating need to replace
filter element
Allows SUCTION PRESSURE GAGE to measure pressure
21
SUCTION PRESSURE
drop across low-pressure filter; in FILTER-OUT posi-
FILTER-OUT control
tion, gage measures pressure at low pressure filter
output; in FILTER IN position, gage measure pressure
at low pressure filter inlet; in CLOSED position, gage
is shut off
When closed, shuts off fluid to FLUID PRESSURE GAGE
FLUID PRESS GAGE SHUT-
22
while external gage is connected to HP GAGE CAL
OFF valve
PORT for calibration; make sure this valve is open
during normal operation of test stand
Table 2-2. Function of Startup Panel Controls
Function
Description
Index No.
When pulled out, enriches engine fuel mixture for starting
1
CHOKE control
engine
In OFF position, engine magneto is grounded; in ON
2
IGNITION SWITCH
position, magneto is ungrounded and 12 volt DC is applied
to electrical circuits
3
THROTTLE control
Push-pull, twist-to-lock control that sets engine speed
governor for desired engine speed
FUSE 10A
Protects electrical circuits from overloads and short
4
circuits
Momentary on type; when held in pu position, starter
5
STARTER switch
solenoid is energized, thereby applying 12 volts DC
momentarily to starter, which starts engine
2-5