TM 5-2350-378-23&P
0011
EJECTOR DOES NOT EXTEND OR RETRACT - Continued
1
2
3
4
5
T00923HDC
Figure 19. Hydraulic Diagnostic Center (HDC) Control Box.
e.
Start engine.
f.
With engine at idle speed and EJECTOR CONTROL lever in FORWARD position, loosen jam nut
(Figure 20, Item 1) on ejector control valve and turn adjusting screw (Figure 20, Item 2) clockwise to
increase pressure; counterclockwise to decrease pressure.
2
1
T00925HDC
Figure 20.
Ejector Control Valve.
g.
Transducer T-2 hydraulic pressure on HDC display (Figure 19, Item 1) should indicate 1,950-2,050 psi
(13,445-15,135 kPa).
03/15/2011Rel(1.8)root(tswp)wpno(T00009)