FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  137    138    139    140    141  142  143    144    145    146    147  
img
.
TM 5-2350-378-23&P
0013
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
STEP
5.
Check if front corner will raise when front suspension control valve is actuated.
Close globe valve (Figure 2, Item 8) and measure pressure on pressure measuring device
(Figure 2, Item 3).
2
1
8
6
7
3
5
4
T01104HDC
Figure 2. No. 1 Right Actuator.
CONDITION/INDICATION
Will front corner raise?
DECISION
YES - Go to Step (8).
NO - Go to Step (6).
0013-5
03/15/2011Rel(1.8)root(tswp)wpno(T00011)