FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
CONDITION/INDICATION
Is transducer T-10 (front left) and T-11 (front right) pressure greater than 2,500 psi (17,238 kPa)?
DECISION
YES - Go to Step (9).
NO - Replace front actuator (TM 5-2350-262-20).
STEP
8.
Perform SPRUNG/UNSPRUNG control valve linkage check.
a.
Hold measuring device (Figure 5, Item 1) on face of SPRUNG/UNSPRUNG control valve
(Figure 5, Item 2).
b.
Have assistant move SPRUNG/UNSPRUNG lever between SPRUNG and UNSPRUNG mode.
c.
Measure distance plunger (Figure 5, Item 3) travels as lever is moved.
2