• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
TROUBLESHOOTING PROCEDURES - FRONT CORNER (LEFT OR RIGHT) DOES NOT RAISE IN SPRUNG

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  144    145    146    147    148  149  150    151    152    153    154  
img
.
TM 5-2350-378-23&P
0013
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
STEP
12.
Check for blockage in line between forward manifold inlet port 9 and main manifold outlet port 9 (Figure 8).
RH MAIN VALVE FRONT-9
RH MAIN MANF FRONT
LH MAIN MANF FRONT
LH FWD MANF-9
INLET PORT 9
LH MAIN MANF FRONT-9
RH FWD MANF-9
OUTLET PORT 9
RH FWD MANF
LH FWD MANF
T01111HDC
Figure 8. Manifold Inlet/Outlet Port 9.
CONDITION/INDICATION
Is there blockage?
DECISION
YES - Clear blockage or replace FWD MNF-9 tube between main forward manifold and LH or RH forward
manifold. Verify problem is solved.
NO - Verify problem with operator.
END OF WORK PACKAGE
0013-12
03/15/2011Rel(1.8)root(tswp)wpno(T00011)