FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
Figure 8. Manifold Inlet/Outlet Port 9.

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  143    144    145    146    147  148  149    150    151    152    153  
img
.
TM 5-2350-378-23&P
0013
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE - Continued
1
2
3
4
5
T01109HDC
Figure 7. Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Is transducer T-7 (left) and T-8 (right) hydraulic pressure greater than 2,500 psi
(17,238 kPa)?
DECISION
YES - Go to Step (11).
NO - Go to Step (12).
STEP
11.
Check for blockage between inlet port 9 of forward manifold and port 9 of No. 1 actuator, and between left
main manifold and No. 1 actuator.
CONDITION/INDICATION
Is there blockage?
DECISION
YES - Clear blockage. Verify problem is solved.
NO - Verify problem with operator.
0013-11