FRONT CORNER (LEFT OR RIGHT) DOES NOT RAISE IN SPRUNG OR UNSPRUNG MODE - Continued
TROUBLESHOOTING PROCEDURES - HYDRAULIC OIL OVERHEATS

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  149    150    151    152    153  154  155    156    157    158    159  
img
.
TM 5-2350-378-23&P
0014
FRONT CORNER (LEFT OR RIGHT) DOES NOT RAISE IN SPRUNG OR UNSPRUNG MODE - Continued
2
2
3
1
3
T01205HDC
Figure 3.
No. 1 Right Actuator Depicted.
d.
Stop engine; relieve hydraulic pressure and connect lines.
CONDITION/INDICATION
Does front corner raise?
DECISION
YES - Verify problem with operator.
NO - Go to Step (7).
STEP
7.
Check for blockage in line between No. 1 and No. 2 actuators.
CONDITION/INDICATION
Is there blockage?
DECISION
YES - Clear blockage or replace line. Verify problem is solved.
NO - Replace No. 2 actuator (TM 5-2350-262-20).
END OF WORK PACKAGE
0014-5/6 blank
03/15/2011Rel(1.8)root(tswp)wpno(T00012)