HYDRAULIC OIL OVERHEATS - Continued
HYDRAULIC OIL OVERHEATS - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  180    181    182    183    184  185  186    187    188    189    190  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
c.
Disable ejector; manually close V23 (Figure 28, Item 1) on DCV bank.
1
T01345HDC
Figure 28.
Directional Control Valve (DCV) Bank.
d.
Using LINE UP or LINE DOWN button (Figure 27, Item 3), select V1 on HDC display
(Figure 27, Item 2).
e.
Close V17 on HDC display (Figure 27, Item 2) by selecting CHANGE POSITION button
(Figure 27, Item 4) on HDC control box.
f.
Using LINE UP or LINE DOWN button (Figure 27, Item 3), select V17 on HDC display
(Figure 27, Item 2).
g.
Close V17 on HDC display (Figure 27, Item 2) by selecting CHANGE POSITION button
(Figure 27, Item 4) on HDC control box.
h.
Start engine.
i.
As assistant holds APRON CONTROL lever in UP position, loosen jam nut (Figure 29, Item 1) while
observing transducer T-1 hydraulic pressure on HDC display (Figure 27, Item 1).
j.
Rotate adjusting screw (Figure 29, Item 2) clockwise to increase pressure; counterclockwise to decrease
pressure, as necessary to obtain desired pressure. Tighten jam nut (Figure 29, Item 1).
2
1
T01346HDC
Figure 29. Apron Relief Valve.
k.
Stop engine; relieve hydraulic pressure.
0015-31