• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 29. Apron Relief Valve.
HYDRAULIC OIL OVERHEATS - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  181    182    183    184    185  186  187    188    189    190    191  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
l.
Manually open V23 (Figure 30, Item 1) on DCV bank.
1
T01345HDC
Figure 30. Apron Relief Valve.
(1)
Using LINE UP or LINE DOWN button (Figure 31, Item 2), select V1 on HDC display
(Figure 31, Item 1).
(2)
Open V1 on HDC display (Figure 31, Item 1) by selecting CHANGE POSITION button
(Figure 31, Item 3) on HDC control box.
(3)
Using LINE UP or LINE DOWN button (Figure 31, Item 2), select V17 on HDC display
(Figure 31, Item 1).
(4)
Open V17 on HDC display (Figure 31, Item 1) by selecting CHANGE POSITION button
(Figure 31, Item 3) on HDC control box.
0015-32
03/15/2011Rel(1.8)root(tswp)wpno(T00013)