TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
CONDITION/INDICATION
Is pressure 3,450-3,550 psi (23,780-24,475 kPa)?
DECISION
YES - Stop engine; relieve hydraulic pressure. Go to Step (25).
NO - Go to Step (24).
STEP
24.
Perform apron relief valve adjustment.
a.
As assistant holds APRON CONTROL lever DOWN, loosen jam nut (Figure 32, Item 6) and rotate
adjusting screw (Figure 32, Item 7) clockwise to increase pressure; counterclockwise to decrease
pressure.
b.
When adjustment is completed, tighten jam nut (Figure 32, Item 6).
c.
Stop engine; relieve hydraulic pressure.
CONDITION/INDICATION
Can pressure be adjusted to 3,450-3,550 psi (23,780-24,475 kPa)?
DECISION
YES - Remove all test equipment and connect lines. Verify problem is solved.
NO - Replace DCV (TM 5-2350-262-20).
0015-35
03/15/2011Rel(1.8)root(tswp)wpno(T00013)