ASSEMBLY
CAUTION
Assembly should be performed in a clean environment and protective dust covers or caps
should be installed on all openings to prevent contamination. Dirt can damage parts and
cause malfunctions.
When securing forward right manifold in vise, exercise extreme care not to mar any
surfaces or damage components.
1.
Install new O-ring (Figure 3, Item 2), transducer T11 (Figure 3, Item 1), two new O-rings (Figure 3, Item 13),
two new packing retainers (Figure 3, Item 14), two new O-rings (Figure 3, Item 15), two new packing retainers
(Figure 3, Item 14), and two two-way (NO) valves V2 and V10 (Figure 3, Item 12) into right forward manifold
(Figure 3, Item 9).
2.
Install new O-ring (Figure 3, Item 4), adapter (Figure 3, Item 5), new O-ring (Figure 3, Item 7), adapter
(Figure 3, Item 6), new O-ring (Figure 3, Item 7), adapter (Figure 3, Item 8), new O-ring (Figure 3, Item 4),
adapter (Figure 3, Item 11), two new O-rings (Figure 3, Item 7), two adapters (Figure 3, Item 10), two new
O-rings (Figure 3, Item 2), and two adapters (Figure 3, Item 3) into right forward manifold (Figure 3, Item 9).
5
6
4
1
3
7
2
8
22
7
14
15
14
13
14
15
14
13
7
10
9
7
10
12
4
11
M0030HDC
Figure 3.
Hydraulic Diagnostic Center (HDC) Forward Right Manifold Assembly.
END OF TASK