TM 5-2350-378-23&P
0037
DISASSEMBLY
CAUTION
Disassembly should be performed in a clean environment and protective dust covers or
caps should be installed on all openings to prevent contamination. Dirt can damage parts
and cause malfunctions.
When securing forward right manifold in vise, exercise extreme care not to mar any
surfaces or damage components.
1.
Remove two adapters (Figure 2, Item 3), two O-rings (Figure 2, Item 2), two adapters (Figure 2, Item 10), two
O-rings (Figure 2, Item 7), adapter (Figure 2, Item 11), O-ring (Figure 2, Item 4), adapter (Figure 2, Item 8),
O-ring (Figure 2, Item 7), adapter (Figure 2, Item 5), O-ring (Figure 2, Item 4), adapter (Figure 2, Item 6), and
O-ring (Figure 2, Item 7) from right manifold (Figure 2, Item 9). Discard O-rings.
2.
Remove two two-way (NO) valves V2 and V10 (Figure 2, Item 12), two packing retainers (Figure 2, Item 14),
two O-rings (Figure 2, Item 15), two packing retainers (Figure 2, Item 14), two O-rings (Figure 2, Item 13),
transducer T11 (Figure 2, Item 1), and O-ring (Figure 2, Item 2) from right manifold (Figure 2, Item 9). Discard
O-rings and packing retainers.
5
6
4
3
7
1
2
8
2
2
7
14
15
14
13
14
15
14
13
7
10
9
7
10
12
4
11
M0029HDC
Figure 2.
Hydraulic Diagnostic Center (HDC) Forward Right Manifold Disassembly.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00009)