Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  418    419    420    421    422  423  424    425    426    427    428  
img
.
TM 5-2350-378-23&P
0041
REMOVAL - Continued
1.
Remove hose (Figure 1, Item 5) from bottom adapter (Figure 1, Item 4) of manual shutoff valve V23
(Figure 1, Item 2).
2.
Remove adapter (Figure 1, Item 4) and O-ring (Figure 1, Item 3) from bottom of manual shutoff valve V23
(Figure 1, Item 2). Discard O-ring.
3.
Remove adapter (Figure 1, Item 6) and manual shutoff valve V23 (Figure 1, Item 2) from port 22 of
Directional Control Valve (DCV) bank (Figure 1, Item 1).
4.
Remove adapter (Figure 1, Item 6) and O-ring (Figure 1, Item 3) from top of manual shutoff valve V23
(Figure 1, Item 2). Discard O-ring.
1
6
3
2
3
4
5
M0050HDC
Figure 1. Manual Shutoff Valve V23 Removal.
END OF TASK
0041-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00015)