TM 5-2350-378-23&P
0041
REMOVAL - Continued
1.
Remove hose (Figure 1, Item 5) from bottom adapter (Figure 1, Item 4) of manual shutoff valve V23
(Figure 1, Item 2).
2.
Remove adapter (Figure 1, Item 4) and O-ring (Figure 1, Item 3) from bottom of manual shutoff valve V23
(Figure 1, Item 2). Discard O-ring.
3.
Remove adapter (Figure 1, Item 6) and manual shutoff valve V23 (Figure 1, Item 2) from port 22 of
Directional Control Valve (DCV) bank (Figure 1, Item 1).
4.
Remove adapter (Figure 1, Item 6) and O-ring (Figure 1, Item 3) from top of manual shutoff valve V23
(Figure 1, Item 2). Discard O-ring.
1
6
3
2
3
4
5
M0050HDC
Figure 1. Manual Shutoff Valve V23 Removal.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00015)