TROUBLESHOOTING PROCEDURES - BUMP STOPS INOPERATIVE - Continued
k.
Stop engine and relieve hydraulic pressure.
l.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 3, Item 5) on the HDC
control box.
1
2
3
4
5
T00706HDC
Figure 3. Hydraulic Diagnostic Center (HDC) Control Box.
CONDITION/INDICATION
Is transducer T-7 hydraulic pressure less than 2,500 psi (17,238 kPa)?
DECISION
YES - Verify with operator that problem is only confined to bump stops.
NO - Clear or replace circuit 9 hoses between bump stop cylinder and left main manifold port
(TM 5-2350-262-20).
0009-5