TROUBLESHOOTING PROCEDURES - BUMP STOPS INOPERATIVE - Continued
CONDITION/INDICATION
Is transducer T-10 (left side) or T-11 (right side) hydraulic pressure less than 2,500 psi (17,238 kPa)?
DECISION
YES - Verify with operator that problem is only confined to bump stop. If so, repair or replace compensating
pump (TM 5-2350-262-20).
NO - Go to Step (8).
STEP
8.
Inspect appropriate circuit II hose between forward manifold and bump stop.
CONDITION/INDICATION
Is ciruit II blocked or damaged?
DECISION
YES - Clear blockage or replace circuit 11 hose between bump stop cylinder and forward manifold
(TM 5-2350-262-20).
NO - Replace solenoid valve V9 (left side) on left forward manifold (WP 0036) or solenoid valve V10 (right
END OF WORK PACKAGE