FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE - Continued
STEP
3.
Perform SPRUNG/UNSPRUNG valve linkage check.
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless ejector
lock is engaged. Failure to comply may result in severe injury or death to personnel.
a.
Hold measuring device (Figure 2, Item 1) on face of SPRUNG/UNSPRUNG control valve
(Figure 2, Item 3).
b.
Have assistant move SPRUNG/UNSPRUNG lever between SPRUNG and UNSPRUNG mode.
c.
Measure distance plunger (Figure 2, Item 2) travels as lever is moved.
1
2
3
T00105HDC
Figure 2. Control Valve Linkage.
d.
Distance of travel should be 9/32 in. (7 mm).
CONDITION/INDICATION
Is linkage correctly adjusted?
DECISION
YES - Go to Step (5).
NO - Go to Step (4).
STEP
4.
Perform SPRUNG/UNSPRUNG control valve linkage adjustment.