HYDRAULIC OIL OVERHEATS - Continued
HYDRAULIC OIL OVERHEATS - Continued

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  195    196    197    198    199  200  201    202    203    204    205  
img
.
TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
STEP
31.
Perform suspension relief valve adjustment using HDC.
a.
Reset all HDC solenoid valves by selecting RESET VALVES button (Figure 39, Item 5) on HDC control
box.
2
1
3
4
5
T01354HDC
Figure 39. Hydraulic Diagnostic Center (HDC) Control Box.
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless
ejector lock is engaged. Failure to comply may result in severe injury or death to
personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in
bowl to observe roller guide travels. Failure to comply may result in severe injury or
death to personnel.
When folding dozer blade, work on blade latches from side of vehicle only. Do not
stand in front of dozer blade while retracting ejector. Failure to comply may result in
severe injury or death to personnel.
b.
Stop engine and relieve hydraulic pressure.
c.
Manually close ejector inhibit ball valve V23 (Figure 40, Item 1) on DCV bank.
0015-46