TM 5-2350-378-23&P
0015
HYDRAULIC OIL OVERHEATS - Continued
1
2
3
4
5
T01353HDC
Figure 38. Hydraulic Diagnostic Center (HDC) Control Box.
k.
Repeat steps and open V12 and V13, and close V19.
l.
Stop engine; relieve hydraulic pressure.
CONDITION/INDICATION
Is transducer T-13 hydraulic pressure 3,700-3,800 psi (25,512-26,201 kPa)?
DECISION
YES - Go to Step (32).
NO - Go to Step (31).
03/15/2011Rel(1.8)root(tswp)wpno(T00013)