0031
INSTALLATION
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless ejector
lock is engaged. Failure to comply may result in severe injury or death to personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in bowl
to observe roller guide travels. Failure to comply may result in severe injury or death to
personnel.
When folding dozer blade, work on blade latches from side of vehicle only. Do not stand
in front of dozer blade while retracting ejector. Failure to comply may result in severe
injury or death to personnel.
1.
Thread wiring harness leads through wire clamps and secure harness with new tie down straps.
2.
Install wiring harness W2 connector J1 (Figure 4, Item 2) to HDC disconnect bracket (Figure 4, Item 5) with
nutplate (Figure 4, Item 1), and four screws (Figure 4, Item 3). Attach dust cap (Figure 4, Item 4) to connector
J1.
1
2
3
5
4
M0015HDC
Figure 4. Wiring Harness W2 Connector J1 at Disconnect Bracket Installation.
0031-5
03/15/2011Rel(1.8)root(maintwp)wpno(M00006)