TM 5-2350-378-23&P
0031
INSTALLATION - Continued
6.
At the main hydraulic pump left and right high-pressure filter area, connect wiring harness W2 connector P3
(Figure 6, Item 6) to transducer T3 (Figure 6, Item 5), wiring harness W2 connector P4 (Figure 6, Item 4) to
transducer T4 (Figure 6, Item 3), and wiring harness W2 connector P30 (Figure 6, Item 1) to transducer T12
(Figure 6, Item 2).
2
1
3
4
5
6
M0017HDC
Figure 6.
Wiring Harness W2 to Filter Area Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Connect negative battery cables (TM 5-2350-262-20).
2.
Return vehicle ejector to stowed position (TM 5-2350-262-10).
3.
Return vehicle apron to stowed position (TM 5-2350-262-10).
END OF TASK
END OF WORK PACKAGE
03/15/2011Rel(1.8)root(maintwp)wpno(M00006)