TM 5-2350-378-23&P
0036
DISASSEMBLY
CAUTION
Disassembly should be performed in a clean environment and protective dust covers or
caps should be installed on all openings to prevent contamination. Dirt can damage parts
and cause malfunctions.
When securing forward left manifold in vise, exercise extreme care not to mar any
surfaces or damage components.
1.
Remove two adapters (Figure 2, Item 3), two O-rings (Figure 2, Item 4), two adapters (Figure 2, Item 12), two
O-rings (Figure 2, Item 13), adapter (Figure 2, Item 11), O-ring (Figure 2, Item 2), adapter (Figure 2, Item 15),
O-ring (Figure 2, Item 13), two adapters (Figure 2, Item 1), and two O-rings (Figure 2, Item 2) from left forward
manifold (Figure 2, Item 14). Discard O-rings.
2.
Remove two two-way (NO) valves V3 and V9 (Figure 2, Item 10), two packing retainers (Figure 2, Item 7), two
O-rings (Figure 2, Item 8), two packing retainers (Figure 2, Item 7), two O-rings (Figure 2, Item 9), transducer
T10 (Figure 2, Item 6), and O-ring (Figure 2, Item 5) from left forward manifold (Figure 2, Item 14). Discard
O-rings and packing retainers.
1
2
3
16
4
6
13
3
5
15
4
7
13
8
7
9
7
8
7
9
13
12
2
14
11
13
10
12
M0025HDC
Figure 2.
Hydraulic Diagnostic Center (HDC) Forward Left Manifold Disassembly.
END OF TASK