TM 5-2350-378-23&P
0036
ASSEMBLY
CAUTION
Assembly should be performed in a clean environment and protective dust covers or caps
should be installed on all openings to prevent contamination. Dirt can damage parts and
cause malfunctions.
When securing forward left manifold in vise, exercise extreme care not to mar any
surfaces or damage components.
1.
Install new O-ring (Figure 3, Item 5), transducer T10 (Figure 3, Item 6), two new O-rings (Figure 3, Item 9),
two new packing retainers (Figure 3, Item 7), two new O-rings (Figure 3, Item 8), two new packing retainers
(Figure 3, Item 7), and two two-way (NO) valves V3 and V9 (Figure 3, Item 10) into left forward manifold
(Figure 3, Item 14).
2.
Install new O-ring (Figure 3, Item 2), adapter (Figure 3, Item 1), new O-ring (Figure 3, Item 13), adapter
(Figure 3, Item 16), new O-ring (Figure 3, Item 13), adapter (Figure 3, Item 15), new O-ring (Figure 3, Item 2),
adapter (Figure 3, Item 11), two new O-rings (Figure 3, Item 13), two adapters (Figure 3, Item 12), two new
O-rings (Figure 3, Item 4), and two adapters (Figure 3, Item 3) into left forward manifold (Figure 3, Item 14).
1
2
3
16
4
6
13
3
5
15
4
7
13
8
7
9
7
8
7
9
13
12
2
14
11
13
10
12
M0026HDC
Figure 3.
Hydraulic Diagnostic Center (HDC) Forward Left Manifold Assembly.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00008)