Possible
remedy
Probable
cause
Air shroud loose or damaged ---------------------------------------- Tighten air shroud. Report damaged shroud to direct
and general support maintenance.
Cylinder cooling fins clogged with dirt ---------------------------- Report malfunction to direct and general support main-
tenance.
Possible
remedy
Probable
cause
oil
level
too
low
---------------------------------------
Stop engine and add
oil
to
proper
level.
Refer
to
lubrication chart.
Possible
remedy
Probable
cause
oil
level
too
low
--------------------------------------
Stop engine and add oil to proper level. Refer to
lubrication chart.
Oil
pressure
gage
defective
-------------------------------------
Report malfunction to direct and general support
maintenance.
Possible
remedy
Probable
cause
Crankcase oil level too high ---------------------------------------- Drain off excess oil to correct level.
Carburetor choked excessively --------------------------------------- Push in choke control.
Engine cold causing poor combustion ----------------------------- Allow sufficient time for engine warm up before oper-
ating the hydraulic system.
Probable
cause
Possible
remedy
Choke control partially closed ---------------------------------- Open choke control.
Dirty air cleaner -------------------------------------------------------- Service the air cleaner (par. 52).
Fuel leaks ---------------------------------------------------------------- Report to direct and general support
maintenance.
Probable
cause
Possible
remedy
Battery electrolyte level low ------------------------------------- Add battery water to correct level (par. 9).
Battery defective ------------------------------------------------------ Replace defective battery (par. 9).
Probable
cause
Possible
remedy
High pressure relief valve out of adjustment ------------ Adjust the high pressure relief valve (par. 43).
Compensator control incorrectly adjusted -------------------- Adjust the compensator control (par. 43).
Fluid bypass valve open ------------------------------------------- Close the fluid bypass valve.
Defective fluid pressure gage ------------------------------------ Report to direct and general support maintenance,
Probable
cause
Possible
remedy
Fluid volume control incorrectly adjusted ------------------ Adjust the fluid volume control (par. 43).
Engine speed incorrect ---------------------------------------------- Set throttle for an indicated 1800 rpm.
Probable cause
Possible
remedy
High pressure relief valve set too high ------------------------- Adjust high pressure relief valve (par. 43).
High pressure relief valve defective ------------------------- Refer the malfunction to direct and general support
maintenance.
Probable
cause
Possible
remedy
Low pressure filter dirty ------------------------------------------------
Report deficiency to direct and general support main-
tenance.
Reservoir fluid level low ----------------------------------------------- Fill reservoir to correct level (par. 9).
AGO 5742A
|