TM 5-2350-378-23&P
0012
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE - Continued
CONDITION/INDICATION
Is transducer T-10 (front left actuator) and T-11 (front right actuator) hydraulic pressure between 2,800-2,900
psi (19,306-19,996 kPa)?
DECISION
YES - Go to Step (17).
NO - Go to Step (16).
STEP
16.
Perform circuit 11 hoses and lines blockage check.
Check for blockage in all hoses and lines applicable to corner of vehicle which will not raise (Figure 12).
RH FWD MANF-11 RH MAIN MANF FRONT-11 SPR-UNSPR VLV-11
RH MAIN MANF
BOT-11
LH MAIN MANF
BOT-11
NO.1 SPNSN
LH FWD MANF-11
FWD
LH MAIN
UNIT-11
MANF-11ELB
MANTOP-11
FWD MANF-11ELB
LH MAIN MANF
NO.1 SPNSN
FRONT-11
UNIT-11
T00117HDC
Figure 12.
Circuit 11 Components, Hoses and Lines.
CONDITION/INDICATION
Is there any blockage?
DECISION
YES - Clear blockage or replace lines. Verify problem is solved.
NO - Verify problem with operator.
STEP
17.
Check lines between actuator and forward manifold.
CONDITION/INDICATION
Is there any blockage?
DECISION
YES - Clear blockage or replace lines. Verify problem is solved.
NO - Go to Step (18).
03/15/2011Rel(1.8)root(tswp)wpno(T00010)