FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE - Continued
Figure 17. Main Relief Valve.

Hydraulic Diagnostic Center (HDC) Supporting Armored Combat Earthmover (ACE), M9
Page Navigation
  128    129    130    131    132  133  134    135    136    137    138  
img
.
TM 5-2350-378-23&P
0012
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE - Continued
c.
Using LINE UP or LINE DOWN button (Figure 16, Item 3), select V1 on HDC display (Figure 16, Item 2).
d.
Close V1 on HDC display (Figure 16, Item 2) by selecting CHANGE POSITION button
(Figure 16, Item 4) on HDC control box.
e.
With SPRUNG/UNSPRUNG lever in SPRUNG, have assistant move left hand SUSPENSION CONTROL
lever to RAISE, while at same time, holding EJECTOR CONTROL lever in BACK.
f.
Observe transducer T-4 hydraulic pressure on HDC display (Figure 16, Item 1).
1
2
3
4
5
T00121HDC
Figure 16. Hydraulic Diagnostic Center (HDC) Control Box.
0012-23