FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE - Continued
STEP
20.
Perform main relief valve adjustment using HDC.
a.
Reset all HDC solenoid valves by selecting RESET VALVES button (Figure 16, Item 5) on HDC control
box.
WARNING
Do not operate ejector when personnel are in bowl. Do not work in bowl unless
ejector lock is engaged. Failure to comply may result in severe injury or death to
personnel.
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in
bowl to observe roller guide travels. Failure to comply may result in severe injury or
death to personnel.
b.
Disable ejector by manually closing ejector inhibit ball valve V23 (Figure 15, Item 1) on DCV bank.
1
T00122HDC
Figure 15. Directional Control Valve (DCV) Bank.
03/15/2011Rel(1.8)root(tswp)wpno(T00010)